Please wait a minute...
文章检索
预防医学  2023, Vol. 35 Issue (2): 152-154    DOI: 10.19485/j.cnki.issn2096-5087.2023.02.015
  疾病控制 本期目录 | 过刊浏览 | 高级检索 |
甲亢患者99mTcO4-甲状腺SPECT检查的周围剂量当量率分析
胡隽, 刘浩, 施燕琴, 俞苏英, 窦超, 赵岚, 王菲菲, 董孟杰
浙江大学医学院附属第一医院核医学科,浙江 杭州 310003
Ambient dose equivalent in 99mTcO4- single photon emission computed tomography of the thyroid among patients with hyperthyroidism
HU Jun, LIU Hao, SHI Yanqin, YU Suying, DOU Chao, ZHAO Lan, WANG Feifei, DONG Mengjie
Department of Nuclear Medicine, The First Affiliated Hospital of School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310003, China
全文: PDF(841 KB)  
输出: BibTeX | EndNote (RIS)      
摘要 目的 了解甲状腺功能亢进症(甲亢)患者行99mTcO4-甲状腺SPECT检查的周围剂量当量率变化,提供辐射防护指导建议。方法 选择某三级甲等医院行99mTcO4- 甲状腺SPECT检查的甲亢患者为研究对象,在注射99mTcO4-后的不同时间、与患者颈部水平不同距离处检测周围剂量当量率,采用广义线性混合模型分析注药后时间、检测距离、甲状腺24 h摄碘率和甲状腺质量对周围剂量当量率的影响。结果 纳入100例甲亢患者,其中男性24例,女性76例;年龄为(38.5±14.0)岁。广义线性混合模型有统计学意义(F=6 610.165,P<0.001);患者甲状腺质量、注药后时间、检测距离对周围剂量当量率的影响有统计学意义(F=57.967、15 988.574、11 200.645,均P<0.001),周围剂量当量率与患者甲状腺质量呈正相关,与注药后时间、检测距离呈负相关。结论 甲亢患者99mTcO4-甲状腺SPECT检查的周围剂量当量率受患者的甲状腺质量、注射后时间和检测距离的影响,推迟与患者接触的时间或与患者保持距离可以有效防护辐射。
服务
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章
胡隽
刘浩
施燕琴
俞苏英
窦超
赵岚
王菲菲
董孟杰
关键词 甲状腺功能亢进症SPECT辐射防护剂量当量率    
AbstractObjective To investigate the changes of ambient dose equivalent rate in 99mTcO4- single photon emission computed tomography (SPECT) of the thyroid among patients with hyperthyroidism, so as to provide insights into radiation protection guidance. Methods Patients with hyperthyroidism who underwent 99mTcO4- SPECT of the thyroid in a tertiary hospital were enrolled. The ambient dose equivalent rate was measured at different time points following 99mTcO4- infection and at sites with different distances from patients' neck, and the effects of time post-injection, distance from patients' neck, 24-hour thyroidal radioiodine uptake and thyroid weight on the ambient dose equivalent rate were examined using a generalized linear mixed model. Results Totally 100 patients with hyperthyroidism were enrolled, including 24 men and 76 women and with a mean age of (38.5±14.0) years. The generalized linear mixed model was statistically significant (F=6 610.165, P<0.001), and patients' thyroid weight, time post-injection and distance from patients' neck significantly affected the ambient dose equivalent rate (F=57.967, 15 988.574, 11 200.645, all P<0.001), and the ambient dose equivalent rate positively correlated with patients' thyroid weight and negatively correlated with time post-injection and distance from patients' neck. Conclusions The ambient dose equivalent rate is affected by patients' thyroid weight, time post-injection and distance from patients' neck among patients with hyperthyroidism undergoing 99mTcO4- SPECT of the thyroid. Delay in contact with patients or keeping distance from patients may be effective for radiation protection.
Key wordshyperthyroidism    single photon emission computed tomography    radiation protection    dose equivalent rate
收稿日期: 2022-10-19      修回日期: 2022-12-28      出版日期: 2023-02-10
中图分类号:  R581.1  
通信作者: 董孟杰,E-mail:dmjlzf2016@zju.edu.cn   
作者简介: 胡隽,本科,主管护师,主要从事核医学护理和护理管理工作
引用本文:   
胡隽, 刘浩, 施燕琴, 俞苏英, 窦超, 赵岚, 王菲菲, 董孟杰. 甲亢患者99mTcO4-甲状腺SPECT检查的周围剂量当量率分析[J]. 预防医学, 2023, 35(2): 152-154.
HU Jun, LIU Hao, SHI Yanqin, YU Suying, DOU Chao, ZHAO Lan, WANG Feifei, DONG Mengjie. Ambient dose equivalent in 99mTcO4- single photon emission computed tomography of the thyroid among patients with hyperthyroidism. Preventive Medicine, 2023, 35(2): 152-154.
链接本文:  
http://www.zjyfyxzz.com/CN/10.19485/j.cnki.issn2096-5087.2023.02.015      或      http://www.zjyfyxzz.com/CN/Y2023/V35/I2/152
[1] LI Y,TENG D,BA J,et al.Efficacy and safety of long-term universal salt iodization on thyroid disorders:epidemiological evidence from 31 provinces of mainland China[J].Thyroid,2020,30(4):568-579.
[2] 冯珏. Graves甲状腺功能亢进症的正确诊断与规范化治疗[J].临床荟萃,2016,31(3):233-236.
[3] 中华人民共和国国家卫生健康委员会.核医学放射防护要求:GBZ 120—2020[S].2020.
[4] 郭佳娣,郦依华,俞顺飞,等.2011—2019年浙江省11家省级医院放射工作人员外照射个人剂量监测结果分析[J].预防医学,2021,33(9):948-950.
[5] 章群,张丹丹,王爱红,等.数字X线检查北仑区成人体表照射剂量参考值研究[J].预防医学,2022,34(4):400-403.
[6] 李亚明,王辉,马婷,等.核医学护士工作手册[M].北京:人民卫生出版社,2015:6-7.
[7] 武含露,闫志华,李祥周,等.分化型甲状腺癌患者131I治疗后诊断性全身显像周围剂量当量率动态变化的研究[J].国际放射医学核医学杂志,2020,44(4):212-216.
[8] GRANLUND C,THILANDER-KLANG A,YLHAN B,et al.Absorbed organ and effective doses from digital intra-oral and panoramic radiography applying the ICRP 103 recommendations for effective dose estimations[J/OL].Br J Radiol,2016,89(1066)[2022-12-28].https://doi.org/10.1259/bjr.20151052.
[9] 中华人民共和国卫生部,中国国家标准化管理委员会.临床核医学的患者防护与质量控制规范:GB 16361—2012[S].北京:中国标准出版社,2012.
[10] 中华人民共和国国家质量监督检验检疫总局.电离辐射防护与辐射源安全基本标准:GB 18871—2002[S].2002.
[11] MOUNTFORD P J.Estimation of close contact doses to young infants from surface dose rates on radioactive adults[J].Nucl Med Commun,1987,8(11):857-863.
[1] 陈峰, 郦依华. 血液辐照工作人员个人剂量监测结果分析[J]. 预防医学, 2020, 32(6): 615-617.
[2] 杨介者, 蒋均, 潘晓红, 徐云, 陈婉君, 何林, 郑锦雷. 基于EPP-Spectrum模型的浙江省艾滋病疫情评估[J]. 预防医学, 2018, 30(7): 649-652,657.
[3] 赵三虎, 吴寿明, 俞顺飞, 赵尧贤, 郦依华, 李新星, 罗进, 宣志强. 浙江省医用放射诊疗设备辐射防护现况调查[J]. 预防医学, 2016, 28(7): 721-722,725.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed