Abstract:Objective To evaluate the radiation dose, operational standardization, and image quality of computed tomography (CT) Ningbo City Medical Imaging Cloud Platform, so as to provide references for optimizing the quality of CT examinations. Methods Six CT devices were randomly selected from the Ningbo City Medical Imaging Cloud Platform. Digital Imaging and Communication in Medicine (DICOM) image data from CT examinations of the head, neck, chest, and abdomen in males aged 36 to 60 years were collected from January 2023 to December 2024. The radiation dose levels were evaluated using the volume CT dose index (CTDIvol) and dose length product (DLP). The coefficient of variation (CV) of CTDIvol and scan length were calculated to assess scan stability. Operational standardization was evaluated using the redundancy rate of scan length and protocol matching degree. Imaging quality was assessed using the signal to noise ratio (SNR) and contrast to noise ratio (CNR). Results A total of 28 897 DICOM images were collected, including 6 730 axial scans of the skull, 2 778 plain scans of the neck, 15 496 plain scans of the chest, and 3 893 plain scans of the abdomen. The typical values of CTDIvol and DLP radiation doses for the head, neck, and chest were all lower than the diagnostic reference levels. The maximum typical values of CTDIvol and DLP for the abdomen were 22.49 mGy and 941.45 mGy·cm, respectively, which were higher than the diagnostic reference levels. The CV values of CTDIvol and scan length ranged from 14.59% to 37.88% and from 8.27% to 44.96%, respectively. The scan stability of head CT was relatively poor, with CV values ranging from 21.74% to 37.88% and from 12.66% to 44.96%, respectively. The redundancy rate of scan length ranged from 6.02% to 74.40%, and the protocol matching degree ranged from 79.80% to 100.00%. The operational standardization of neck CT was relatively poor, with redundancy rates ranging from 45.70% to 74.40% and protocol matching degrees ranging from 79.80% to 95.36%. The mean SNR and mean CNR of the pulmonary arteries in the chest were relatively high, ranging from 15.81 to 17.65 and from 6.33 to 7.41, respectively. Conclusions The radiation doses from abdominal CT examinations on some CT devices exceed the diagnostic reference levels. The scan stability of head CT examinations and the operational standardization of neck CT examinations represent weak points in quality control. It is recommended to carry out targeted quality control training to enhance the overall quality level of CT examinations.
章群, 张丹丹, 王永, 张良, 邹沅杰, 陆蓓蓓, 汤升. 基于宁波市影像云平台的CT检查大数据分析[J]. 预防医学, 2025, 37(12): 1257-1260,1265.
ZHANG Qun, ZHANG Dandan, WANG Yong, ZHANG Liang, ZOU Yuanjie, LU Beibei, TANG Sheng. CT examination big data based on the Ningbo City Medical Imaging Cloud Platform. Preventive Medicine, 2025, 37(12): 1257-1260,1265.
[1] DELIS H,CHRISTAKI K,HEALY B,et al.Moving beyond quality control in diagnostic radiology and the role of the clinically qualified medical physicist[J].Phys Med,2017,41:104-108. [2] WAHLER N,KAA BACHI B,KULYNYCH B,et al.Evaluating synthetic data augmentation to correct for data imbalance in realistic clinical prediction settings[J/OL].Stud Health Technol Inform,2024[2025-11-10] .https://doi.org/10.3233/SHTI240563. [3] 国家市场监督管理总局,国家标准化管理委员会.中国成年人人体尺寸:GB/T 10000—2023[S].北京:中国标准出版社,2023. State Administration for Market Regulation,Standardization Administration of the People's Republic of China.Human dimensions of Chinese adults:GB/T 10000—2023[S].Beijing:Standards Press of China,2023.(in Chinese) [4] VAÑÓ E,MILLER D L,MARTIN C J,et al.ICRP publication 135:diagnostic reference levels in medical imaging[J].Ann ICRP,2017,46(1):1-144. [5] 中华人民共和国国家卫生健康委员会.放射诊断放射防护要求:GBZ 130—2020[S].北京:中国标准出版社,2020. National Health Commission of the People's Republic of China. Requirements for radiological protection in diagnostic radiology:GBZ 130—2020[S].Beijing:Standards Press of China,2020.(in Chinese) [6] 魏巍,杨旭,童小雨,等.深度学习重建算法联合低剂量增强CT对肝脏低对比度病灶显示的影响[J].中国医学计算机成像杂志,2024,30(3):333-337. WEI W,YANG X,TONG X Y,et al.Effect of deep learning reconstruction algorithm combined with low-dose contrast-enhanced CT on liver low-contrast lesion[J].Chin Comput Med Imag,2024,30(3):333-337.(in Chinese) [7] MULLINS M E,LEV M H,BOVE P,et al.Comparison of image quality between conventional and low-dose nonenhanced head CT[J].AJNR Am J Neuroradiol,2004,25(4):533-538. [8] 丁晨寒,宋凤祥,杨泽铖.低管电压联合顺适性低剂量容积双空间迭代重建技术在头颈部CT血管成像中的应用[J].中国医学影像学杂志,2024,32(4):379-385. DING C H,SONG F X,YANG Z C.Low tube voltage combined with adaptive iterative dose reduction using three-dimensional processing in head and neck CT angiography[J].Chin J Med Imag,2024,32(4):379-385.(in Chinese) [9] MCCULLOGH C,CODY D,EDYVEAN S,et al.The measurement,reporting,and management of radiation dose in CT[M].Maryland:American Association of Physicists in Medicine,2008. [10] PARK I,SONG J,KIM K.SU-F-I-40:impact of scan length on patient dose in abdomen/pelvis CT diagnosis[J].Med Phys,2016,43(6):3395-3396. [11] LIAO E A,QUINT L E,GOODSITT M M,et al.Extra Z-axis coverage at CT imaging resulting in excess radiation dose:frequency,degree,and contributory factors[J].J Comput Assist Tomogr,2011,35(1):50-56. [12] LONG Z Y,BRUESEWITZ M R,DELONE D R,et al.Evaluation of projection- and dual-energy-based methods for metal artifact reduction in CT using a phantom study[J].J Appl Clin Med Phys,2018,19(4):252-260. [13] ALZUFRI H S,NURMIATI D.The influence of CT parameters for optimizing radiation dose and CT scan image quality in head and abdominal examinations at Cibinong Sentra Medika Hospital[C].Prosiding Seminar Si-INTAN,2023,3(1):17-22. [14] DUERDEN L,O'BRIEN H,DOSHI S,et al.Impact of an ultra-low dose unenhanced planning scan on CT coronary angiography scan length and effective radiation dose[J/OL].BJR Open,2022,4(1)[2025-11-10] .https://doi.org/10.1259/bjro.20210056. [15] O'NEILL E K,COGLEY J R,MILLER F H.The ins and outs of liver imaging[J].Clin Liver Dis,2015,19(1):99-121. [16] 吴一田,耿建华,杜召猛,等.PET/CT中CT自动管电流调制模式下受检者有效剂量的研究[J].中国辐射卫生,2018,27(1):39-43. WU Y T,GENG J H,DU Z M,et al.Study on the effective dose of CT in PET/CT on automatic tube current modulation[J].Chin J Radiol Health,2018,27(1):39-43.(in Chinese) [17] WANG R,XU X J,HUANG G,et al.Comparison of image quality,diagnostic accuracy and radiation dose between flash model and retrospective ECG-triggered protocols in dual source computed tomography(DSCT)in congenital heart diseases[J].Pol J Radiol,2017,82:114-119. [18] KIM D,JEON P H,LEE C L,et al.Effect of tube voltage and radiation dose on image quality in pediatric abdominal CT using deep learning reconstruction:a phantom study[J/OL].Symmetry,2023,15(2)[2025-11-10] .https://doi.org/10.3390/sym15020501.